CN EN
Home > Products > Industrial vacuum cleaner > Jinjie JGY80-40 Industrial Heavy-Dust Vacuum Cleaner
Jinjie JGY80-40 high-power industrial heavy-dust vacuum banner
Start with your site

First find the industrial suction task at industrial power workstations near you

What problem are you trying to solve?

JGY80-40: First, separate the materials, routes, and maintenance for review.

Selecting the wrong collection medium

The same dust or debris may have different temperatures, particle sizes, moisture levels, and hazard classifications; therefore, industrial power station dust collection systems also need to be checked against the medium type.

Only consider the rated power.

Industrial fan, filter element, and fixed work station compatibility; suction port, flexible hose, filter clogging, and container loading also affect on-site wastewater recovery.

Maintenance and cleaning disconnection

Arrange the fixed work station with air line load, stoppage, cleaning, and transfer to avoid repeated interruption of cleaning tasks.

Site conditions, configuration and selection

How does the JGY80-40 work with your site?

Fixed production station

Power supply circuit, start-stop, and operating duration

Workshop area cleaning

Collecting material, tools, and hose distance.

Peripheral suction of the device

Equipment downtime, suction inlet, and maintenance space

Collection points requiring regular filter cleaning

Dust load, filter material, and discharge organization.

Site taskPay attention to the configuration and conditionsSelection check
Fixed production stationPower supply circuit, start-stop, and operating durationFirst verify the industrial power supply and control conditions on-site, then arrange the workstations.
Workshop area cleaningCollecting material, tools, and hose distance.The air flow and vacuum level should be compared separately, not just based on the rated power.
Peripheral suction of the deviceEquipment downtime, suction inlet, and maintenance spaceClean the external equipment according to the job permit, avoiding dangerous operating positions.
Collection points requiring regular filter cleaningDust load, filter material, and discharge organization.Include filter cleaning, emptying the hopper, and machine inspection in the shift plan.

Prepare material photos, suction distance, and power supply conditions.

Please also specify the daily collection capacity, working hours, and the location for filter cleaning and disposal; whether it is applicable should be determined based on the machine's configuration and on-site testing. Without obtaining the corresponding certification, it should not be used for processing flammable and explosive dust, toxic dust, hot chips, or corrosive media.

Typical applications

JGY80-40 in use

TECHNICAL SPECIFICATIONS

Technical specifications

First check the configurations related to the task, then verify the complete specifications and delivery version.

Full specifications for View
Configuration itemThis machine's page records
Airflow318m³/h
Vacuum pressure260mbar
Filter area32000cm²
Container capacity80L
Suction diameter40mm
Power Supply Usage380V
Rated power4.0kW
Motor typeIndustrial fan
Product modelJGY80-40
Filtration methodPolyester fiber filter element
Filter-cleaning methodManual dust removal cleaning
Jinjie JGY80-40 Industrial Heavy-Dust Vacuum Cleanermain image on white background
JGY80-40 machine overall appearance; particulars and internal locations to be verified separately.
Look at the picture to understand the equipment.

Components and their functions

The overall view of the machine shows the appearance of the machine; the following numbers are function description indexes, and do not claim to be verified internal component positions.

01 body and dust collection bucket

Integrate the loading, emptying, and work station layout of the hopper.

02 Industrial Fan

Check the rated power supply and control conditions, and operate within the load specified in the machine's manual.

03 Polyester Fiber Filter

Check the filter material against the material properties, inspect the seal and any damage.

04 Manual Dusting

Clean the filter according to the instructions. Any changes in suction capacity should be checked in combination with the filter material and air circuit.

05 suction inlet and hose

In accordance with the interface and suction distance, avoid flattening, leakage, and blockage.

06 Shutdown and Maintenance

Maintenance requires turning off the machine and implementing isolation, and it is not acceptable to use filter cleaning as a substitute for a full inspection.

Operating process

Connect the industrial power source workbench dust collection to form a complete process.

The following is an operational organization description, which is not the internal air circuit cross-section of this machine.

01 check the material to be collected

Power supply circuit, start-stop, and operating duration; first exclude incompatible and hazardous materials

02 Matching Tools

Check the filter material according to the material properties, inspect the seal and damage. The suction head and air lines should be checked against the interface of this machine.

03 Zone Collection

Combine fixed production workstations and task scheduling to plan the route, paying attention to container, suction, and filtration status.

04 Emptying and Maintenance

Maintenance requires turning off the machine and implementing isolation, and it is not acceptable to use filter cleaning as a substitute for a full inspection.

Professional configuration

Why does the fixed work position and air circuit load affect the selection?

Fixed position and air line load.

Industrial fan, filter element, and fixed work station compatibility; it needs to be verified together with actual medium, attachments, and operation time period.

Filtering is not a single area number.

The compatibility of filter material, cleaning, sealing, and collection is jointly influential on maintenance; no certification can be assumed for special dust protection.

Check the air circuit and transportation together

Hose length, bends, tools, filter material load, and emptying methods should be included in trial operation; rated parameters do not equal field wastewater recovery speed.

Comparison of similar models

Combine the tasks, not just looking at the model numbers.

The middle is this model, and the left and right are configuration or material task references; different tasks do not mean simple high or low grades.

Comparison criteriaJinjie JGY-3078P Industrial Wet/Dry Vacuum Cleaner — main image on white backgroundJGY-3078PJinjie JGY80-40 Industrial Heavy-Dust Vacuum Cleanermain image on white backgroundJGY80-40Jinjie JGY100-75 white-background main imageJGY100-75
Main tasksCold-state metal chips and workbench cleaningIndustrial power source workbench dust collectionLarge-diameter industrial collection and separation system
Selection focusMetal shavings and filter matching.Fixed position and air line load.Inlet diameter, container and optional separator
Power supply220V380V380V
Rated power3600W4.0kW7.5kW
Container80L80L100L
Filter cleaning.Unwoven fabric star-type filterPolyester fiber filter elementPolyester fiber filter element
Cleaning and routine maintenanceHand-pull reverse blowManual dust removal cleaningManual dust removal cleaning
Operating cost

Calculate the entire shift's dust collection for the industrial power workbench.

Equipment and accessories

Include the machine, compatible nozzle and hose, filter media and necessary collection attachments in the quotation. List optional extras separately.

Costs During Use

Record the actual power consumption, operation time, fixed work position, and airway load, without directly converting the saved proportion using the rated power.

Maintenance and disposal

Compare emptying, filter use, servicing and waste disposal on the same basis. A payback estimate requires these operating figures.

MAINTENANCE

Daily inspection focus for JGY80-40

Machine and dust collector

Integrate bucket loading, emptying, and work station layout. Specific disassembly, cycle, and consumables shall be carried out in accordance with the machine's manual.

Industrial fan

Check the rated power supply and control conditions, and operate within the load specified in the machine's manual. Specific disassembly, cycle, and consumables should be carried out according to the machine's manual.

Polyester fiber filter element

Check the filter material according to the material properties, inspect the seal and damage. Specific disassembly, cycle, and consumables should be carried out according to the manual of this machine.

Manual dusting

Clean the filter according to the instructions. Any changes in suction capacity should be checked in combination with the filter material and air circuit. Specifically, the disassembly, cycle, and consumables should be carried out according to the machine's manual.

Suction port and hose.

According to the interface and suction distance, avoid flattening, leakage, and blockage. Specific disassembly, cycle, and consumables should be carried out according to the manual of this machine.

Machine shutdown and maintenance

Maintenance requires turning off the machine and implementing isolation, and it is not acceptable to use filter cleaning as a substitute for a full inspection. Specific disassembly, cycles, and consumables should be carried out according to the machine's manual.

Delivery and after-sales service

Arrange delivery and maintenance around the machine's configuration

Delivery inspection

Verify the model number, nameplate, random accessories, and documentation.

Operator training

Understand start/stop, collection, emptying, and abnormal stop procedures as specified in the machine's manual.

Usage guidance

Combine the industrial power source workbench dust collection to clarify the applicable conditions and job boundaries.

Parts supply

Check the spare parts against the machine's version, interface, and filter material.

On-site fault repair

Fault description and inspection records should be provided first; service scope and arrangements shall be according to the actual agreement.

Scheduled on-site maintenance

Check the agreed content, location, and cost for the equipment and working conditions.

— FAQ

You may also be interested in JGY80-40

Which jobs suit JGY80-40?

This machine is more suitable for industrial power fixed workstations and workshop cleaning, combined with an industrial fan, filter element, and dust collection bucket. The selection focus is on air circuit load and dust removal scheduling.

Why should the focus be on fixed workstations and air circuit load?

Industrial fan, filter element, and fixed work station compatibility; actual selection also needs to be combined with power supply circuit, start-stop, and operation duration.

Can it handle flammable, explosive, or toxic dust?

Without corresponding protection and applicable evidence, cannot recommend the general industrial vacuum configuration; hot chips, sparks, and corrosive media require separate evaluation.

How to verify the power supply and working time?

Based on the machine's nameplate, delivery version, and on-site circuit determination; the operation, filter cleaning, emptying, and transfer time are respectively verified, without committing to rated parameters for actual efficiency.

What are the key points of comparison with JGY-3078P?

The previous model focuses on metal debris and filtration compatibility, while this model emphasizes fixed workstations and air circuit load; compare based on medium and configuration, not on model numbers.

When suction decreases, first check the filter element.

First, follow the instructions to shut down the machine, then check for blockage in the suction hose, load in the container, filter material, and seal. Do not directly determine motor damage, and do not disassemble while powered.

Can the filter material and suction head be used interchangeably?

You cannot assume it is universal. Interfaces, materials, versions, and collection media should all be verified. You should not rely on the accessories configuration of a similar model for assurance.

What information should be prepared before consultation?

Provide photos of fixed production workstations, collect the nature and quantity of the collected materials, the distance of the hose, power supply, working hours, and the disposal point, and together determine if it is suitable.

JGY80-40 factory workshop floor

Judge together whether JGY80-40 is suitable

Please specify the power supply circuit, start-stop, and operation duration, and supplement the power supply, suction distance, and daily operation schedule. We will combine this machine's configuration comparison tool with filtration and disposal solutions.

Phone consultation: 0755-25621811